Features:
Rebound tonometer, also known as impact tonometer, adopting an innovative sensing
rebound technology. The probe will be magnetized when being inserted into the
tonometer and generates N/S poles. An transient current in the solenoids of the device
(lasting about 30 milliseconds) produces an transient magnetic field that causes the
magnetized probe to move towards the cornea at 0.2m/s (homopolar repulsion
principle). The probe bounces on the anterior surface of the cornea, slowing down and
rebounding. If the ocular pressure is increased, the decelaration of the probe increases,
and the duration of the impact decreases.
The electrical control switch monitors the solenoid voltage caused by the rebound of
the magnetized probes,and the electrical signals processors and the microsensors
calculates the deceleration of the probe after impacting the cornea. Finally the
integrated information is converted into ocular pressure readings.
Rebound tonometer is an electric measuring type pressure guage which converts the
presurre into the voltage or current signal through the physical characteristics of the
metal.
Tonometer can obtain the measurement data within 0.1secs.

Applicability:
Used in tonometery tests by ophthalmologists,optometrists,general physician,professional health advisors.

Usage:
1. Turn on the tonometer and install the probe.
2. Move the machine close to the eyes and adjust the distance
3. Gently press the button and obtain the single measurement vaules and average
values in several times.
Short measuring time ,only seconds.
Capacable of storing the ocular data of some ten patients.

Measuring Current 0-6A
Measuring Voltage DC3V
Measuring Range 3mmHg~70mmHg
Weight 300g
Max Probe Speed 0.2m/s
Product Dimensions 110mmx190mmx30mm
Package Dimensions 240mmx280mmx90mm
Working Temperature Range +5℃~+40℃
Working Humidity Range ≤80%
Working Atmospheric Range 700 hpa~1060hpa
Storage Temperature Range -20℃~+55℃
Storage Atmospheric Range 500 hpa~1060hpa
Storage Humidity Range ≤95%
Accuracy Class(3mmHg≤intraocular pressure≤25mmHg) ±1.5mmHg
Accuracy Class(25mmHg≤intraocular pressure≤70mmHg) ±2.5mmHg